Mirus Onics Harmonic Mitigating Power Center

MIRUS Onics Harmonic Mitigating Power Center 
  • Proven Harmonyâ„¢ or Ulltraâ„¢ High Efficiency Transformer reliability
  • Dual electrostatic shield for noise suppression
  • Smaller footprint and significantly lower losses than isolation transformers

Product Details

MIRUS Onics Harmonic Mitigating Power Center

The Onics HMPC is an outstanding power distribution unit ideal for the raised floor environment. It incorporates MIRUS' patented and proven Harmonic Mitigating Transformer (HMT) technology.

Features:

Isolation Transformer Option:

• Proven Harmony™ or Ulltra™ High Efficiency Transformer reliability
• High transformer efficiencies maintained over a wide load range, not just at light load levels
• Harmonic Mitigating Transformer (HMT) options include patented Harmony-2E which treats all four major current harmonics (3rd, 5th, 7th & 9th) by flux cancellation within secondary windings
• All HMT transformers prevent triplens from circulating in the primary windings
• Dual electrostatic shield for noise suppression
• Harmonic losses lowered both within transformer and in upstream distribution

Autotransformer Option:

• Unique and patent pending autotransformer configuration provides significant energy savings in 415V Data Center applications. Allows for
the use of standard 480V UPS systems
• Only autotransformer suitable for 3-wire In / 4-wire Out but requires local electrical authority approval. No special approval required for
4-wire In / 4-wire Out applications.
• Built-in harmonic mitigation treats all four major harmonics (3rd, 5th, 7th & 9th)
• Smaller footprint and significantly lower losses than isolation transformers

MIRUS Drive Tamers Transformers Designed to replace standard drive isolation transformers, the Drive Tamerâ„¢ is built to not only withstand the harsh harmonic environment produced by Varia...
MIRUS Drive 24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24â„¢ pr...
MIRUS Lineator 1Q3 1-Phase to Quasi 3-Phase Harmonic Filter The only passive harmonic filter designed for 3-phase VFD's operating on a 1-phase supply. In remote locations such as farms...
MIRUS Harmony-2E Isolation Transformers and Auto Transformers HARMONYâ„¢ SERIES isolation transformers and autotransformers combine very low zero sequence impedance outputs with phase shift...