MEGGER TTR300 Series Three-Phase Transformer Turns Ratio Test Set 
  • Stand-alone or remote-control operation
  • Accurately measures ratio, phase deviation and excitation current
  • Works in the presence of high interference/high voltage

Product Details

MEGGER TTR300 Series Three-Phase Transformer Turns Ratio Test Set

Stand-alone or remote-control operation, Accurately measures ratio, phase deviation and excitation current, Field upgradeable without compromise to calibration, Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model), Works in the presence of high interference/high voltage, Highest ratio measurement (45,000:1); highest accuracy (0.1%), Displays % error vs. name plate with pass/fail limits

The TTR300 Series of three-phase transformer turns ratio test sets are designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments. Our leads are specially designed to provide the necessary flexibility needed in cold weather.

The TTR300 Series are ideal for use by power transformer manufacturers. Their unique testing procedures and storage capability allows an operator to set up and test difficult three-phase transformers (with multiple tap changers and bushing CTs) in a fraction of the time than it used to take with other TTRs. This test also includes a pass/fail limit of individual ratios.

MEGGER MTO210 Transformer Ohmmeter Direct 2-channel digital reading (1 µO to 2000 O). DC test current up to 10 A maximum. 0.25% measurement accuracy. Integrated demagnetization feature. T...
EuroSMC ETP Test System For Predictive Maintenance In Power Transformers ETP SYSTEM is a complete predictive maintenance instrument to detect the problems before unexpected failures appea...
OMICRON TMDRA 100 Simulation of Power Transformers Response Curves The TMDRA 100 is an accessory for OMICRON's DIRANA. It simulates typical dielectric response curves of power transformer...
MEGGER IDAX300 Insulation Diagnostic Analyzer Fast and accurate moisture assessment in power transformers. Well proven technology; IDA/IDAX units have been in field use 10+ years. Reliabl...
EuroSMC ETP-3 Winding Resistance Measurement Unit The measurement equipment ETP-3 is a unit that automatically performs the following measurements in all type of power, distribution, or i...