Free Call Australia : 1 800 834 991

Related Products

Hioki 3801-50 Digital HiTester

HIOKI 3801-50 Digital HiTester 
  • High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement)
  • Can record to internal memory, maximum, minimum, or average value
  • High-precision measurement at the 3801-50 Basic accuracy ±0.025 %, 1 µV minimum resolution

Product Details

HIOKI 3801-50 Digital HiTester

High Performance, Superior Functionality, and Advanced Safety

High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement). Can record to internal memory, maximum, minimum, or average value. High-precision measurement at the 3801-50 Basic accuracy ±0.025 %, 1 µV minimum resolution. Depend on a dual-display, can display two parameter. Convenient back-light display on dark environment. For PC measurement corresponds to USB communication (optional)

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

Basic specifications (Accuracy guaranteed for 1 year)

DC Voltage /51000 dgt. : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.025 % rdg. ±5 dgt.

AC Voltage /45 to 1 kHz : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.4 % rdg. ±25 dgt.
Frequency characteristics: 20 Hz - 100 kHz

Resistance : 510.00 O to 510.00 MO, 510.00 nS, 8 ranges (3802-50: up to 51.000 MO, 510.00 nS, 7 ranges)
Basic accuracy: ±0.05 % rdg. ±5 dgt.

DC Current : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.05 % rdg. ±25 dgt.

AC Current /45 to 2 kHz : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.7 % rdg. ±20 dgt.
Frequency characteristics: 20 Hz - 100 kHz

C (capacitance) : 9.999 nF (resolution 1 pF) to 99.99 mF (rosolution 10 µF), 8 ranges
Basic accuracy: ±1.5 % rdg. ±5 dgt.

Continuity buzzer : 1000 digits or less at resistance measurement

Diode check : Open terminal voltage: 4.8 V, Testing current: 1 mA

Hz (Frequency, Volt function) : 99.999 Hz to 999.99 kHz 5 ranges, ±0.02 % rdg. ±3 dgt.

Hz counter : Divide 1: 99.999 Hz to 9.9999 MHz
Divide 100: 9.9999 MHz to 99.999 MHz
Accuracy: ±0.002 % rdg. ±3 dgt.

Duty ratio : 99.99 % , Basic accuracy: ±0.3 %/kHz ±0.3 %

Pulse width : 510.00 ms to 1999.9 ms, Accuracy: ±0.2 % rdg. ±3 dgt. at 10 µs over pulse width

Temperature measure : -200.0 °C to 1372.0 °C (Thermo-couple K), -210.0 °C to 1200.0 °C (Thermocouple J), Accuracy: ±0.3 % rdg. ±3 °C add probe accuracy, (the 3802-50: K type only)

Pulse output : 0.5 Hz to 4800 Hz, change duty ratio possible

Other function : AC+DC mode

dBm mode, Recoding (Max./ Min. / Ave.), Relative value, Peak hold, Trriger hold, Auto-power save, Terminal A improper connection warning, Back light

Display : Digital/ LCD, max. 51000 digits

Sample rate : 3.75 times/s (V and, A measurement)

Power supply : Stacked battery (6F22 or 6LR61) ×1, Continuous use: 50 hours (6LR61)

Dimensions and mass : 100W (3.94in) × 202H (7.95in) × 57D (2.24in) mm, 680 g (24.0 oz) (with holster and battery)

Supplied accessories : TEST LEAD×1, Strap×1, Holster×1, Instruction Manual×1, Stacked Alkaline Battery (6LR61)×1 (for trial purposes only)

HIOKI 3805-50 Digital HiTester Demonstrate the Power of your DMM during Facilities Maintenance For Instrumentation (4 - 20mA% display). For Power line distortion check (Harmonic distor...
HIOKI 3244-60 Card HiTester Compact ! Palm size body, Less than 1cm thin ! Better contact test leads with tip pin length 15mm and gold-plated. Only 9.5 mm(0.37 in) thick and 60 g(2.1 o...
FLUKE 77 IV Series Digital Multimeter The NEW Fluke 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has...
HIOKI 3257-50 Digital HiTester Terminal shutter interlock mechanism for safety 3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulate...
RISHABH RISH Multi 15S Handheld Digital Multimeter The automatic Terminal blocking system prevents incorrect connection of the test leads and incorrect selection of the measured quantity....