Free Call Australia : 1 800 834 991

Related Products

Hioki 3290 Clamp-On AC/DC HiTester

HIOKI 3290 Clamp-On AC/DC HiTester 
  • Absolute value (of waveform peak)
  • Separate constituent element of AC, DC
  • Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)

Product Details

HIOKI 3290 Clamp-On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up

Choice of three sensors (Example combinations)
3290/3290-10 +9691 : Measure up to 100A
3290/3290-10 +9692 : Measure up to 200A
3290/3290-10 +9693 : Measure up to 2000A

Choice of measurement methods
DC (for battery measurement)
AC+DC RMS (for full-/half-wave rectification measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement) of inrush current, etc.)

Choice of output (Simultaneous output)
Effective value output, frequency output, waveform output

3290-10 Functions
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement

Measurement method : DC, AC+DC (True RMS), AC (True RMS/ Average rectified)

Peak value display : Absolute value (of waveform peak)

Separate AC from DC output : Separate constituent element of AC, DC

Output (terminal 1) : Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)

Output (terminal 2) : Rms current/Low-battery warning switch

Integral current measurement : None

Rate measurement : None

Timer settings : None

Data storage : None

Basic accuracy at DC current : 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the 9692 sensor) : ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the 9693 sensor) : ±1.8 % rdg. ±1.0 A/ ±5 A

Basic accuracy at AC current
(45 to 66 Hz) 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the 9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A

Voltage measurement : None

Frequency measurement : 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.

Crest factor : 2.5 or later, or rated peak value of sensor

Frequency characteristic : DC, or 1 Hz to 1 kHz (accuracy guaranteed range)

At monitor output : based on the using sensor

Other functions : Selectable of responce time, filter (fc=550 Hz)

Power supply : LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)

Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)

Supplied accessories : Carrying strap ×1, LR6 (AA) alkaline batteries × 4

HIOKI 3293-50 Clamp-On Leak HiTester Easily read measured values from all heights with the adjustable display Measure for leakage current and load all with the same device. Innovative fl...
HIOKI 3286-20 Clamp-On Power HiTester Functionality and Safety Packed into a Handheld Unit Single phase 600 kW & up to 20th Harmonic levels measurement. Active/ reactive/ apparent power,...
HIOKI 3282 Digital Clamp-On HiTester The true RMS is shown in the distorted waveform You can choice two models, measurement current up to 600A or 1000A. AC current, Voltage, Frequency, Re...
HIOKI 3287 Clamp-On AC/DC HiTester Compact & easy, one-touch maintenance on all types of AC/DC equipment Model 3287: True RMS . Can measure a small current use with 10 A range. Voltage, R...
HIOKI CM4374 AC/DC Clamp Meter is the best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4374 is a 2000A True RMS clamp meter that features ...