Free Call Australia : 1 800 834 991

Related Products

Omicron CP CU1 Multifunctional Coupling Unit for CPC 100 

OMICRON CP CU1 Multifunctional Coupling Unit for CPC 100 
  • Line impedances and k-factors of overhead lines or high-voltage cables
  • Ground impedances of large systems
  • Coupling of power lines into signal cables

Product Details

OMICRON CP CU1 Multifunctional Coupling Unit for CPC 100

The CPC 100 + CP CU1 measure line impedances and k-factors on overhead lines and power cables. Ground impedances can also be determined on large systems with the CP CU1, as well as touch and step voltages.

Mains frequency malfunctions do not influence the measurements, as the CPC 100 + CP CU1 use variable output frequencies for measurements. This enables extremely precise and reproducible measurement results.

To increase safety for the test engineer, the CP GB1 grounding unit is supplied with the CP CU1. This can divert currents of up to 30 kA if its voltage limit value is exceeded.

Key features

• Measurement is not affected by mains frequency interference - extremely precise measurement results are obtained
• Compliance with the strictest safety standards for overhead lines and cables connections - diverting currents up to 30 kA
• Easy to handle - heaviest component: 29 kg
• Automatic logging: Results are recorded automatically by the software

Applications

• Line impedances and k-factors of overhead lines or high-voltage cables
• Ground impedances of large systems
• Step and touch voltages
• Mutual coupling of parallel overhead lines
• Coupling of power lines into signal cables

MEGGER DELTA3000 10-kV Automated Insulation Power Factor Test Set Integrated PowerDB software package allows for automated control without the use of a laptop. Extremely easy to use, with...
OMICRON MI 600 Precise measurement of Dissipation Factor, Power Factor and Capacitance The MI 600 is a precise measurement and analysis system for the dissipation factor (tan delta), powe...
OMICRON CP TD1 Capacitance/Dissipation Factor Testing Device (Tan Delta) Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laborato...
MEGGER CB-100 Low Voltage Capacitance Lightweight and portable, 100-Hz test frequency & 30-V output voltage . Designed for testing in the laboratory, shop or substation, Model CB-100 i...