Free Call Australia : 1 800 834 991

Related Products

Mirus AutoTrans Lineator Harmonic Mitigation Filters

MIRUS AutoTrans Lineator Harmonic Mitigation Filters 
  • It is a low voltage passive harmonic mitigation
  • The use of 6-pulse Variable Speed Drives and other static power conversion equipment
  • No other device on the market can meet the limits of IEEE STD 519 at an equivalent size, efficiency and cost

Product Details

MIRUS AutoTrans Lineator Harmonic Mitigation Filters

The use of 6-pulse Variable Speed Drives and other static power conversion equipment has grown rapidly in recent years. With this growth has come concern over the level of current harmonics generated by such equipment. Harmonic currents and the voltage distortion these currents create can have devastating effects on a power distribution system and its connected equipment. Present methods of harmonic treatment on low voltage 6-pulse VFD applications where the VFD voltage rating is different from the service voltage, require a special replacement 18-Pulse VFD, or a separate transformer to match the existing 6-Pulse VFD voltage along with tuned passive filters, or expensive active filters.

The innovative AutoTranslineatorâ„¢ is the best advance in the area of low voltage passive harmonic mitigation available today. No other device on the market can meet the limits of IEEE STD 519 at an equivalent size, efficiency and cost. When the application calls for harmonic treatment for low voltage 6-pulse VFD applications where the VFD voltage rating is different from the service voltage, the AutoTranslineatorâ„¢ is the only logical choice.

MIRUS GENLINK Dissimilar Pitch Neutral Limiter GENLINK DPNL is a multiple winding reactor and when installed in the common neutral of paralleled sources either between the dissimilar gene...
MIRUS Onics Harmonic Mitigating Power Center The Onics HMPC is an outstanding power distribution unit ideal for the raised floor environment. It incorporates MIRUS' patented and proven Ha...
MIRUS Lineator 1Q3 1-Phase to Quasi 3-Phase Harmonic Filter The only passive harmonic filter designed for 3-phase VFD's operating on a 1-phase supply. In remote locations such as farms...
MIRUS Drive Tamers Transformers Designed to replace standard drive isolation transformers, the Drive Tamerâ„¢ is built to not only withstand the harsh harmonic environment produced by Varia...
MIRUS Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters An easy to apply, passive filter capable of reducing Variable Speed Drive (VSD) / Variable Frequency Drive (VFD) harmonics ...