Free Call Australia : 1 800 834 991

Related Products

Hioki 3802-50 Digital HiTester

HIOKI 3802-50 Digital HiTester 
  • High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement)
  • Can record to internal memory, maximum, minimum, or average value
  • For PC measurement corresponds to USB communication (optional)

Product Details

HIOKI 3802-50 Digital HiTester

High Performance, Superior Functionality, and Advanced Safety

High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement)
Can record to internal memory, maximum, minimum, or average value
High-precision measurement at the 3801-50 Basic accuracy ±0.025 %, 1 µV minimum resolution
Depend on a dual-display, can display two parameter
Convenient back-light display on dark environment
For PC measurement corresponds to USB communication (optional)

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

Basic specifications (Accuracy guaranteed for 1 year)

DC Voltage /51000 dgt. : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.03 % rdg. ±5 dgt.

AC Voltage /45 to 1 kHz : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.6 % rdg. ±25 dgt.
Frequency characteristics: 30 Hz - 30 kHz

Resistance : 510.00 O to 510.00 MO, 510.00 nS, 8 ranges (3802-50: up to 51.000 MO, 510.00 nS, 7 ranges)
Basic accuracy: ±0.08 % rdg. ±5 dgt.

DC Current : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.1 % rdg. ±25 dgt.

AC Current /45 to 2 kHz : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.8 %rdg. ±20 dgt.
Frequency characteristics: 30 Hz - 20 kHz

C (capacitance) : 9.999 nF (resolution 1 pF) to 99.99 mF (rosolution 10 µF), 8 ranges
Basic accuracy: ±1.5 % rdg. ±5 dgt.

Continuity buzzer : 1000 digits or less at resistance measurement

Diode check : Open terminal voltage: 4.8 V, Testing current: 1 mA

Hz (Frequency, Volt function) : 99.999 Hz to 999.99 kHz 5 ranges, ±0.02 % rdg. ±3 dgt.

Hz counter : Not available
Accuracy: ±0.002 % rdg. ±3 dgt.

Duty ratio : 99.99 % , Basic accuracy: ±0.3 %/kHz ±0.3 %

Pulse width : 510.00 ms to 1999.9 ms, Accuracy: ±0.2 % rdg. ±3 dgt. at 10 µs over pulse width

Temperature measure : -200.0 °C to 1372.0 °C (Thermo-couple K), -210.0 °C to 1200.0 °C (Thermocouple J), Accuracy: ±0.3 % rdg. ±3 °C add probe accuracy, (the 3802-50: K type only)

Pulse output : Not available

Other function : Not available
dBm mode, Recoding (Max./ Min. / Ave.), Relative value, Peak hold, Trriger hold, Auto-power save, Terminal A improper connection warning, Back light

Display : Digital/ LCD, max. 51000 digits

Sample rate : 3.75 times/s (V and, A measurement)

Power supply : Stacked battery (6F22 or 6LR61) ×1, Continuous use: 50 hours (6LR61)

Dimensions and mass : 100W (3.94in) × 202H (7.95in) × 57D (2.24in) mm, 680 g (24.0 oz) (with holster and battery)

Supplied accessories : TEST LEAD×1, Strap×1, Holster×1, Instruction Manual×1, Stacked Alkaline Battery (6LR61)×1 (for trial purposes only)

HIOKI 3245-60 Solar HiTester Environmentally-friendly DMM Hybrid power system incorporates both a solar-charged main battery and a backup battery. Pocket-sized CATIII (600V) and CATIV ...
HIOKI 3239-01 Digital HiTester Benchtop 5-1/2 digits DMM with 4-terminal resistance measurement and high-accuracy Multi functional and high precision model, with 4-terminal resistance ...
METREL MD 9015 Digital Multimeter The digital multimeter MD 9015 includes all the functions needed to detect most electrical and electrotechnical problems. Offering one-handed operation a...
APLAB Model 305 4¾ Digit 80 Segment High End Multimeter Aplab-APPA multimeter 305 is designed for harsh environments with water tight gaskets at the seams, rotary switch, input terminals,...
HIOKI 3239 Digital HiTester Benchtop 5-1/2 digits DMM with 4-terminal resistance measurement and high-accuracy Multi functional and high precision model, with 4-terminal resistance mea...