EuroSMC ETP-2 Recovery Voltage And Insulation Measuring Unit

EuroSMC ETP-2 Recovery Voltage And Insulation Measuring Unit 
  • Quality Control after the manufacturing process
  • Reception of new or repaired transformers
  • Detection of possible problems during the maintenance task itself

Product Details

EuroSMC ETP-2 Recovery Voltage And Insulation Measuring Unit

The transformers testing equipment ETP-2, is a unit that automatically performs the following measurements in all type of power, distribution, or instrument transformers:

- Recovery Voltage of the insulation.
- Insulation resistance.
- Polarization Index.

To measure these parameters, the unit applies different levels of DC test voltage through an internal programmable automatic DC voltage supply. The measured values are acquired automatically in the specified time. The equipment evaluates the actual general status of the insulation, and detects possible ageing problems in the quality of the paper/oil insulation.

APPLICATIONS

The user-friendly software, quick measuring speeds, and the ability to get instantaneous organized results (on the screen, recorded or printed), the ETP-2 has great advantages when performing the following tasks:
- Quality Control after the manufacturing process.
- Reception of new or repaired transformers.
- Detection of possible problems during the maintenance task itself.
- Integrates the data inside a predictive maintenance program.

The recovery voltage test, designed for oil insulated transformers, is a new outstanding technology which allows advanced diagnostic of the paper insulation status and ageing, without considering the status of the insulation oil. It is a great advance, due to the fact that until now, there is no other method to know the paper insulation status, without extracting it from the inside of the transformer.

At the same time that the recovery voltage test occurs, the insulation resistance test, the polarization index and the time constant test are performed as well, delivering all the necessary complementary information for a proper and accurate evaluation of the general insulation status.

The automatic recording of the successive test results creates a database, which allows a trend analysis and an early detection of possible problems in the insulation. The following types of voltage transformers can be tested with the ETP-2, despite the size and power:
- Power Transformers (single or three phase).
- Distribution Transformers (single or three phase).
- Power Autotranformers (single or three phase).
- Instrument Voltage Transformers.
- Current Transformers.

CHARACTERISTICS
- Fully automatic Recovery voltage test in all the test cycles of voltage application, discharge of the insulation and measurement acquisition.
- Automatic generation of the measured values on each test cycle graphic representation.
- Total test time of 40 minutes using the time base of 100 ms.
- The connection to the transformer is guided from the computer to avoid connection errors.
- All measurement processes are automatic and the results do not depend of the user personal criteria.
- Results values are automatically corrected to a reference temperature enablig, standard results.
- Numerical and graphic presentation give the results of the following parameters:
Recovery Voltage.
Raising time of the capacity.
Insulation resistance.
Time constant.
Polarization Index.

The graphic curves gives very important information about the evolution of the obtained values, which makes the diagnostic of possible problems fast and easy.
- The control program allows selecting the following possibilities to perform the insulation tests:
HV + LV against Ground.
HV against LV + Ground.
HV against LV + Tertiary + Ground.

MEGGER PowerDB Test Data Management Software The Megger PowerDB is a powerful software package providing data management for each of your acceptance and maintenance testing jobs. Custo...
EuroSMC ETP-4 Short Circuit Impedance Measurement Unit The measurement equipment ETP-4 is a unit that automatically performs the following measurements in all type of power, distribution,...
OMICRON TMDRA 100 Simulation of Power Transformers Response Curves The TMDRA 100 is an accessory for OMICRON's DIRANA. It simulates typical dielectric response curves of power transformer...
WUHAN HUAYING HYZC 10 Transformer DC Resistance Tester General introduction HYZC Series Transformer DC Resistance Tester uses Constant current source to measure the DC resistance of in...
MEGGER IDAX300 Insulation Diagnostic Analyzer Fast and accurate moisture assessment in power transformers. Well proven technology; IDA/IDAX units have been in field use 10+ years. Reliabl...